- Help Center
- Cyclovac - North America
- FAQ - *DATASYNC ONLY* Maintenance & Installation
-
Cyclovac - North America
-
Retraflex & Retractable system
-
Mvac - North America
-
Beam
-
Cana-Vac - North America
-
Rhino Vac
-
SuperVac - North America
-
AirStream - North America
-
Bags, Filters & UV Lamp
-
Hayden - North America
-
CycloUV - Air Purifier UVC
-
HD Commercial Line
-
Autorized Dealer Section
-
Motors and Electric Component
-
Replacement parts
-
Serial Number
-
Various parts - TTP
-
Carbon brushes
-
other products
GX710 Unit maintenance
1. Problem, with a GX710 that stops after a few minutes of use. :
The motor and electronic board (RELAY) have been changed but not the Datasync screen on the front of the unit, and it still shuts down during use.
→ What could be the problem? If the motor and relay have been changed, the problem is most likely the Datasync screen which is called the Datasync Information Center. Depending on the results, you may or may not need to replace the Datasync screen.
→ How do you bypass that little screen there? You can bypass to test if it is indeed the screen that creates the shutdown without reason during use.
-
- First you have to disconnect the screen.
- Then "short" the low voltage wire, using a paper clip that we will unfold, we will disconnect the wires and use the ends of the paper clip to insert in each color, 1 in the red and 1 in the black.
- If the motor starts, it means that the screen is defective.
Part Number: ELELCD62